Test Code AAGFS Alpha-3 Beta-4 Ganglionic Neuronal Acetylcholine Receptor Binding Antibody, Flow Cytometry, Serum (Non-Orderable)
Specimen Required
Only orderable as part of profile. For more information see:
-DYS2 / Dysautonomia, Autoimmune/Paraneoplastic Evaluation, Serum
-GID2 / Gastrointestinal Dysmotility, Autoimmune/Paraneoplastic Evaluation, Serum
Secondary ID
622854Useful For
Only orderable as a reflex. For more information see:
DYS2 / Dysautonomia, Autoimmune/Paraneoplastic Evaluation, Serum
GID2 / Gastrointestinal Dysmotility, Autoimmune/Paraneoplastic Evaluation, Serum
Evaluating patients with suspected autoimmune autonomic ganglionopathy and autoimmune gastrointestinal dysmotility using serum specimens
Reporting alpha-3 beta-4 ganglionic neuronal acetylcholine receptor binding antibody results as part of a profile
Reflex Tests
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| AAGTS | AChR Alpha3 Gang Flow Titer, S | No | No |
Testing Algorithm
When the results of this assay require further evaluation, the reflex titer test will be performed at an additional charge.
Method Name
Only orderable as part of profile. For more information see:
-DYS2 / Dysautonomia, Autoimmune/Paraneoplastic Evaluation, Serum
-GID2 / Gastrointestinal Dysmotility, Autoimmune/Paraneoplastic Evaluation, Serum
Flow Cytometry
Reporting Name
AChR Alpha3 Ganglionic Flow, SSpecimen Type
SerumSpecimen Minimum Volume
Serum: 1 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 28 days |
| Frozen | 28 days | |
| Ambient | 72 hours |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
| Gross icterus | Reject |
Clinical Information
The assay for ganglionic acetylcholine receptor binding antibodies (alpha-3 beta-4) is most useful as a screening test for autoimmune autonomic ganglionopathy (AAG), a form of autoimmune dysautonomia which can manifest as pandysautonomia (several of fixed pupillary dilatation, orthostatic hypotension, sweat loss, gastroparesis, small bowel pseudo-obstruction, constipation and urinary retention due to bladder hypocontractility) or limited forms such as autoimmune gastrointestinal dysmotility. Occasionally, AAG may occur in a paraneoplastic context accompanying diverse carcinomas or thymoma. AAG is generally an immune therapy responsive disease.
Reference Values
Only orderable as part of profile. For more information see:
-DYS2 / Dysautonomia, Autoimmune/Paraneoplastic Evaluation, Serum
-GID2 / Gastrointestinal Dysmotility, Autoimmune/Paraneoplastic Evaluation, Serum
Negative
Interpretation
Seropositivity for ganglionic acetylcholine receptor binding autoantibodies supports the clinical diagnosis of autoimmune autonomic failure with neurological presentations including orthostatic hypotension, constipation, dilated pupils, dry eyes and dry mouth, fainting, urinary retention. Immune therapies such as corticosteroids, plasma exchange and intravenous immunoglobulin may lead to disease remission.
Method Description
This assay is a live cell–based binding assay using flow cytometry to detect ganglionic acetylcholine receptor (AChR) binding antibodies in patient serum. Human embryonic kidney cells (HEK293) transiently expressing human alpha-3 beta-4 ganglionic AChR subunits, along with accessory proteins required for receptor expression, are used as the antigen source. Receptor expression is enhanced prior to analysis under controlled culture conditions. Cells are incubated with diluted patient serum to allow binding of AChR-specific antibodies to surface-expressed receptors. Bound human IgG is detected using a fluorophore-conjugated anti-human IgG secondary antibody, with a viability dye included to exclude non-viable cells. Fluorescence intensity is measured by flow cytometry, and antibody binding is assessed by comparing signal from AChR-expressing cells to control cells lacking receptor expression. A humanized AChR-specific monoclonal antibody is used as an assay calibrator. The IgG binding index (IBI) of patient samples is compared to the assay calibrator to calculate a cut-off Index (COI). Patient samples with a COI greater than or equal to 1.0 are reported as positive. Positive samples are further titrated to determine the end-point dilution, defined as the highest serum dilution that remains above the calibrator.(Unpublished Mayo method)
Day(s) Performed
Varies
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86255
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| AAGFS | AChR Alpha3 Ganglionic Flow, S | In Process |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 622854 | AChR Alpha3 Ganglionic Flow, S | In Process |