Test Code ALCU Aluminum/Creatinine Ratio, Urine
Specimen Required
Only orderable as part of a profile. For more information see ALUCR / Aluminum/Creatinine Ratio, Random, Urine.
Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine collection container
Submission Container/Tube: Plastic urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect a random urine specimen.
2. See Metals Analysis Specimen Collection and Transport for complete instructions.
Secondary ID
610839Useful For
Measurement of aluminum concentration as a part of assessing for aluminum exposure
Method Name
Only orderable as part of a profile. For more information see ALUCR / Aluminum/Creatinine Ratio, Random, Urine.
Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
Reporting Name
Aluminum/Creat Ratio, USpecimen Type
UrineSpecimen Minimum Volume
0.7 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Under normal physiologic conditions, the usual daily dietary intake of aluminum (5-10 mg) is eliminated completely. Excretion is accomplished by avid filtration of aluminum from the blood by the glomeruli of the kidney. Patients in kidney failure lose the ability to clear aluminum and are candidates for aluminum toxicity.
Many factors increase the incidence of aluminum toxicity in patients with kidney failure:
-Aluminum-laden dialysis water can expose dialysis patients to aluminum.
-Aluminum-laden albumin can expose patients to an aluminum burden they cannot eliminate.
-The dialysis process is not highly effective at eliminating aluminum.
-Aluminum-based phosphate binder gels are administered orally to minimize phosphate accumulation; a small fraction of this aluminum may be absorbed and accumulated.
If it is not removed by kidney filtration, aluminum accumulates in the blood where it binds to proteins such as albumin and is rapidly distributed through the body. Aluminum overload leads to accumulation of aluminum at two sites: brain and bone. Brain deposition has been implicated as a cause of dialysis dementia. In bone, aluminum replaces calcium at the mineralization front, disrupting normal osteoid formation.
Urine aluminum concentrations are likely to be increased above the reference range in patients with metallic joint prosthesis. Prosthetic devices produced by Zimmer Company and Johnson and Johnson typically are made of aluminum, vanadium, and titanium. This list of products is incomplete, and these products change occasionally; see prosthesis product information for each device for composition details.
Reference Values
Only orderable as part of a profile. For more information see ALUCR / Aluminum/Creatinine Ratio, Random, Urine.
Not applicable
Interpretation
Daily excretion more than 10 mcg/24 hours indicates exposure to aluminum.
Prosthesis wear is known to result in increased circulating concentration of metal ions.(1) Modest increase (10-20 mcg/24 hours) in urine aluminum concentration is likely to be associated with a prosthetic device in good condition. Urine concentrations more than 50 mcg/24 hours in a patient with an aluminum-based implant, not undergoing dialysis, suggest significant prosthesis wear. Increased urine trace element concentrations in the absence of corroborating clinical information do not independently predict prosthesis wear or failure.
In kidney failure, the ability of the kidney to excrete aluminum decreases, while the exposure to aluminum increases (aluminum-laden dialysis water, aluminum-laden albumin, and aluminum-laden phosphate binders).
Patients receiving chelation therapy with desferrioxamine (for iron- or aluminum-overload states) also excrete considerably more aluminum in their urine than normal.
Method Description
The metal of interest is analyzed by inductively coupled plasma mass spectrometry.(Unpublished Mayo method)
Day(s) Performed
Tuesday
Performing Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82108
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
ALCU | Aluminum/Creat Ratio, U | 13470-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
610839 | Aluminum/Creat Ratio, U | 13470-0 |