Sign in →

Test Code FANTI Anti-IgE


Specimen Required


Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Serum

Collection Instructions:

1. Centrifuge and aliquot 1 mL of serum into a plastic vial.

2. Send refrigerate


Method Name

ELISA

Reporting Name

Anti-IgE

Specimen Type

Serum

Specimen Stability Information

Specimen Type Temperature Time
Serum Ambient (preferred) 7 days
  Frozen  28 days
  Refrigerated  7 days

Reject Due To

  All specimens will be evaluated by the processing and performing laboratories for test suitability.

Reference Values

Normal

Day(s) Performed

Wednesday

Performing Laboratory

Eurofins Viracor

CPT Code Information

83516

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FANTI Anti-IgE Not Provided

 

Result ID Test Result Name Result LOINC Value
FANTI Anti-IgE Not Provided

Specimen Minimum Volume

Serum: 0.5 mL

Clinical Information

Refer to www.eurofins-viracor.com/test-menu

Test Classification

This test was developed and its performance characteristics determined by Eurofins Viracor. It has not been cleared or approved by the U.S. Food and Drug Administration.