Sign in →

Test Code FFWNC Walnut Component rJug r 3


Specimen Required


Specimen Type: Serum

Container/Tube: Red or SST

Specimen Volume: 0.5 mL

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.


Secondary ID

75584

Method Name

ImmunoCAP FEIA

Reporting Name

Walnut Component rJug r 3

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  84 days
  Ambient  28 days

Reject Due To

Gross hemolysis: Reject
Thawing: Warm OK; Cold OK
Gross lipemia: Reject
Gross icterus: NA
Other: NA

Reference Values

<0.10 kU/L

Interpretation

Class

IgE (kU/L)

Comment

0

<0.10

Negative

0/1

0.10 - 0.34

Equivocal/Borderline

1

0.35 - 0.69

Low Positive

2

0.70 - 3.49

Moderate Positive

3

3.50 - 17.49

High Positive

4

17.50 - 49.99

Very High Positive

5

50.00 - 99.99

Very High Positive

6

>99.99

Very High Positive

Method Description

The ImmunoCAP FEIA method uses as the solid phase a flexible, hydrophobic cellulosic polymer to which allergen has been covalently linked. The advantage of this system is that it has a very high antigen binding capacity when compared to other systems and it has minimal non-specific binding with high total IgE.

Performing Laboratory

Eurofins Viracor

Test Classification

This test has been cleared or approved for diagnostic use by the U.S. Food and Drug Administration.

CPT Code Information

86008

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FFWNC Walnut Component rJug r 3 81789-0

 

Result ID Test Result Name Result LOINC Value
Z5674 Walnut Component rJug r 3 81789-0
Z5675 Class 103118-6