Test Code MAGES Myelin-Associated Glycoprotein Autoantibodies, IgM, Serum
Specimen Required
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Forms
If not ordering electronically, complete, print, and send a Neurology Specialty Testing Client Test Request (T732) with the specimen.
Secondary ID
607034Useful For
Evaluating peripheral neuropathy
Evaluating paraproteinemic neuropathy
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)Reporting Name
MAG IgM, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 72 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Clinical Information
Autoantibodies directed against myelin-associated glycoprotein (MAG) are associated with sensory motor demyelinating peripheral neuropathy. A distal acquired demyelinating symmetric (DADS) neuropathy phenotype is the most commonly associated presentation. Patients typically have a slowly progressive symmetric sensory ataxia with/without distal weakness and an IgM monoclonal gammopathy of undetermined significance. Nerve conductions studies typically demonstrate a characteristic progressive sensory predominant mixed axonal and demyelinating neuropathy with reduced distal conduction velocities that are greater distally. In general, patients with a DADS neuropathy show limited treatment responses to intravenous immunoglobulin and more aggressive immunotherapy may be needed. MAG antibody titers do not correlate with disease severity nor treatment responses. The presence of MAG antibodies is not exclusively diagnostic of an acquired neuropathy and results must be interpreted in the correct clinical and electrophysiological context. MAG antibodies are present in approximately 50% to 70% of those with an IgM M-protein and a DADS neuropathy phenotype. However, MAG antibodies may also be identified in those with an IgM M-protein and a chronic inflammatory demyelinating polyneuropathy (CIDP) presentation as well as in other IgM paraproteinemic disorders that present with neuropathy including in myeloma, lymphoplasmacytic lymphoma (Waldenstrom macroglobulinemia) and amyloid light chain (AL)-IgM primary amyloidosis. Higher MAG antibody titers (>10,000 Buhlmann titer unit) are better predictors of an electrophysiological DADS phenotype whereas low titer MAG antibodies may be associated with a more diverse group of neuropathies. Detection of MAG IgM antibody by enzyme-linked immunosorbent assay based on human MAG (100 kDa) antigen is significantly more sensitive and specific than MAG western blot and immunofluorescence assays using primate antigen.
Reference Values
<1500 Buhlmann Titer Unit
Interpretation
A positive result is consistent with anti-myelin-associated glycoprotein neuropathy.
Method Description
Microwells are precoated with human myelin-associated glycoprotein (MAG) antigen. The calibrators, controls, and diluted patient samples are added to the wells, and autoantibodies recognizing the MAG antigen bind during the first incubation. After washing the wells to remove all unbound proteins, purified horseradish peroxidase-labeled anti-human IgM conjugate is added. The conjugate binds to the captured human autoantibody, and the excess unbound conjugate is removed by a further wash step. The bound conjugate is visualized with 3,3',5,5'-tetramethylbenzidine substrate, which gives a blue reaction product, the intensity of which is proportional to a concentration of autoantibody in the sample. Acid is added to each well to stop the reaction. This produces a yellow end-point color, which is read at 450 nm.(Package insert: anti-MAG Autoantibodies ELISA. Buhlmann Laboratories AG; 10/2018)
Day(s) Performed
Tuesday, FridayPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
83520
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MAGES | MAG IgM, S | 39087-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
607034 | MAG IgM, S | 39087-2 |